DUAL GAS VALVE GH-469
01 Max. performance range per hour with p=2mb
- LP: 39,200 BTU / 11,4 kW / 41,0
MJ with 50mb operating pressure
- NG: 18,400 BTU / 5,3 kW / 19,3
MJ with 20mb operating pressure
- TG: 8,900 BTU / 2,6 kW / 9,4
MJ with 8mb operating pressure
02 Max. operating pressure
- 65mb
03 Max. operating temperature
- 248° F / 120°C
- 302° F / 150°C
according to standards
04 Gas inlet
- Saddle connection with clamp
for tube 16 mm or 21 mm
05 Gas outlet
- External thread 1/2-24 UNS
(olive for tube 5/16“)
- Internal thread 3/8-24 UNF
(olive for tube 3/16”)
06 Approved in cooktops
- CSA Group
07 Applicable standard
- EN 126 (European Standard)
- Z21.15 USA (American Standard)