Aliquam lorem ante, dapibus in, viverra quis, feugiat a, tellus. Phasellus viverra nulla ut metus varius laoreet. Quisque rutrum. Aenean imperdiet.

Latest News

    No posts were found.

Share this
admin

GAS VALVE GH-676

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]GAS VALVE GH-676 With flame failure device.[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 24,600 BTU / 7,2 kW / 26,0 MJ with 50mb operating pressure NG: 13,700 BTU / 4,0 kW / 14,4 MJ with...

admin

GAS VALVE GH-675

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]GAS VALVE GH-675[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 27,300 BTU / 8,0 kW / 28,8 MJ with 50mb operating pressure NG: 16,400 BTU / 4,8 kW / 17,3 MJ with 20mb operating pressure ...

admin

DUAL GAS VALVE GH-620

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]DUAL GAS VALVE GH-620[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 115,200 BTU / 33,5 kW / 120,8 MJ with 50mb operating pressure NG: 55,000 BTU / 16,0 kW / 57,7 MJ with 20mb operating pressure ...

admin

GAS VALVE GH-521

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]GAS VALVE GH-521[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 83,000 BTU / 24,3 kW / 87,5 MJ with 50mb operating pressure NG: 42,300 BTU / 12,4 kW / 44,6 MJ with 20mb operating pressure ...

admin

DUAL GAS VALVE GH-520

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]DUAL GAS VALVE GH-520[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 115,200 BTU / 33,5 kW / 120,8 MJ with 50mb operating pressure NG: 55,000 BTU / 16,0 kW / 57,7 MJ with 20mb operating pressure ...

admin

DUAL GAS VALVE GH-486

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]DUAL GAS VALVE GH-486[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 39,200 BTU / 11,4 kW / 41,0 MJ with 50mb operating pressure NG: 18,400 BTU / 5,3 kW / 19,3 MJ with 20mb operating...

admin

GAS VALVE GH-467

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]GAS VALVE GH-467[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 44,400 BTU / 12,9 kW / 46,5 MJ with 50mb operating pressure NG: 21,000 BTU / 6,1 kW / 22,0 MJ with 20mb operating pressure ...

admin

DUAL GAS VALVE GH-469

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]DUAL GAS VALVE GH-469[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 39,200 BTU / 11,4 kW / 41,0 MJ with 50mb operating pressure NG: 18,400 BTU / 5,3 kW / 19,3 MJ with 20mb operating...

admin

GAS VALVE GH-468

[vc_row][vc_column][vc_column_text css_animation="fadeInDown"]GAS VALVE GH-468[/vc_column_text][/vc_column][/vc_row][vc_row css_animation="mkd-element-from-fade" css=".vc_custom_1643001328361{padding-bottom: 65px !important;}"][vc_column width="1/2"][mkd_accordion style="accordion"][mkd_accordion_tab icon_pack="" title="Max. performance range per hour with p=2mb" skin="dark" number="01" number_color="#1d2c4d"][vc_column_text] LP: 44,400 BTU / 12,9 kW / 46,5 MJ with 50mb operating pressure NG: 21,000 BTU / 6,1 kW / 22,0 MJ with 20mb operating pressure ...